Bondaglass G4 Pond Seal
Seals Concrete Ponds
| |
Features
- G4 Pond Seal is a moisture cured Polyurethane Waterproofer and sealer for concrete,
brick, porous stone, and waterfalls.
- 3 coat application.
- Quick - Simple
- No primer needed
- Seals out lime
- Can be used at low temperature.
- Excellent for repairing hairline cracks
in concrete, as well as waterproofing and sealing
- Available in a variety of
colours.
|
|
| |
Surface Preparation
- Ensure that concrete render is clean, dry, and porous - highly trowelled
surfaces are not advised. New render should be allowed to harden for
21 - 28 days depending on conditions. Reinforcing fibres in the
cement render must be burnt or sanded off before coating
- If using on an old pond, repair any cracks or replace damaged areas, and
allow repairs to dry.
- Ensure surface is clean, any algae is removed, brush off dust and remove
loose material.
|
|
| |
Application
G4 Standard
- Apply first coat of G4 by brush - a roller can be used but it is
necessary to avoid puddling of the G4 on the base, so it is best to use a
brush.
- Allow first coat to become tacky (like cellotape) or dry enough to walk
carefully upon - about 60-90 minutes depending on humidity.
- Apply 2nd coat.
- When second coat is finger tacky apply third coat.
- No longer than four hours should elapse between coats.
- Normally 3 coats of G4 Standard is sufficient. On very porous substrates a 4th coat may be required (apply as instructed above).
- If rain is expected make provisions for covering the coated area, since
water can damage the G4 during the curing process
- Allow to harden for 72 hours before washing down with clean water.
G4 Colour
- When using coloured G4 the first two coats must be G4
standard, this is because the G4 standard provides the maximum non porous
seal and adhesion.
- Follow the application instructions detailed earlier but the last two
coats will be G4 coloured.
|
|
| |
Other Materials
G4 cannot be used to seal over bitumen, P.V.C.
or Butyl Rubber linings. It will not bond to the P.V.C. or Butyl Rubber
although it will not attack them.
|
|
| |
Cure (Hardening)
G4 is mechanically hard after 24 hours and walkable on some
6 hours after final application. However, 72 hours must elapse for full
chemical cure, before washing down the G4 with copious amounts of clean
water. This water should be cleaned off. The pool can then be
filled.
If rain is expected make provisions for covering the coated
area, since water can damage the G4 during the curing process. As soon
as it is superficially dry water should not affect G4
|
|
| |
Warnings
& Cautions
- Do not apply in wet or humid conditions.
- Protect from rain during the curing process.
Medical
Information
- Skin - Wipe off and wash with soap
and water.
- Eyes - Rinse thoroughly for 10
minutes and seek medical attention.
- Inhalation - In case of irritation
of the respiratory tract move into fresh air and seek
medical attention.
- Ingestion - Seek medical attention
- In all
cases of doubt seek medical attention
Before using the user should
determine the suitability of the product for the intended
use. This information is offered in good faith but
without guarantee or liability.
|
|
Buy it Now
from www.aquatics-online.co.uk